Appendix 2. Message List
AP2-6
13. Notice 9013: (ADE) Inclinometer read fault.
It is an error output for FELCOM-500, and the status for this error is confirmed
during selftest.
This message will be output when abnormality is detected in the EL inclination sensor.
It implies a failure in the ATB Module or in the sensor. Please replace the Front end
Module (ATB/LNA assembly)
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
14. Notice 9014: (ADE) Accelerometer read fault.
The status for this error is confirmed during selftest.
This message will be output when abnormality is detected for the EL acceleration
sensor. It implies a failure in the ATB Module or in the sensor. Please replace the
Front end Module (ATB/LNA assembly)
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
15. Notice 9015: (ADE) Temperature low.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when the temperature for the ADE Module is too low.
Please wait for a while until the temperature gets higher.
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
16. Notice 9016: (ADE) Temperature high.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when the temperature for ADE is too high (+75 degrees).
Please wait for a while until the temperature gets lower.
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
17. Notice 9017: (ADE) RF synthesizer: PLL repeatedly loses lock.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when RF PLL does not get locked. Please replace the
Front end Module (ATB/LNA assembly)
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.