2.1 MF/HF (150/250W) system
2-2
2.1.1 FS-2550/1562 system setting
1) Changing system setting
Set the system channels as shown in Table 2.1.1. Make the other settings as per
customers requests.
Table 2.1.1
Setting
System
channel
Function
FS-1562
-15
FS-1562
-25
FS-2550
Note
9900 Country of delivery
0:
Standard
0:
Standard
1:
GMDSS
Standard
/GMDSS
9902
Tx frequency
selection
0:Free 1:Marine
2:ROM 3:Marine free
Depend on
requests
9904 TLX usage 0 0 0 Enable
9906 Tx delay time 10 ms 10 ms 10 ms
9908 AM usage 1 1 1 Rx only
9911
Emission mode on
2182 kHz
3 3 3 J3E fix
9915 Tx TUNE 0 0 0 Enable
9916
Remote control
format
0 0 MIF
9917
EM mode with Tx key
ON from external
equipment
0 0 0 No change
9928
Priority setting on
2182 kHz
1 1 1 Priority: DSC
9997
Selection of output
power
0:(150W)
AT-1560-15
2:(250W)
AT-1560-25
2:(250W)
AT-1560-25
9999 Password 1562 1562 75
Procedure of the setting:
1. FS-1562 : Turn on power holding down [RCL] key.
FS-2550 : Turn on power holding down [CH] key.
2. Select “9999” by turning [FREQ/CH] knob.
3. FS-1562 : Press [RCL] key, enter 1562”, and press [ENT] key.
FS-2550 : Press [CH] key, enter “75”, and press [ENT] key.
4. Select system channel to be set by turning [FREQ/CH] knob.
5. FS-1562 : Press [RCL] key, enter the set value, and press [ENT] key.
FS-2550 : Press [CH] key, enter the “set value”, and press [ENT] key.
6. To make other settings, repeat the steps 4 and 5.
7. Turn off power.