2.1 MF/HF (150/250W) system
2-11
2.1.2 DSC-60 system setting
Necessary are to set MMSI, each item in the Setup menu, and DIP switches on
CONTROL/MODEM board.
To make the settings of SYSTEM in the Setup menu, Protection must be set to OFF.
(Refer to the next page.)
Set and confirm the items in Table 2.1.7. Set the other settings as per customers
requests.
Table 2.1.7
Setting menu Setting Note
MMSI 9 digits
Distress 2M+8M+4/6/12/16M
SCAN FERQ
Routine F1 - F6
EX)
International
frequencies
WATCH RCVR MF/HF
LINE OUT 0 dBm
TX-KEY
TIMING
AUTO
RT PORT MIF
REMOTE
STATION
ON
NBDP PORT ON
CH DET
S LEVEL
100
Setup menu
SYSTEM
REGULATION International
S3 #1,2-ON, #3,4-OFF NBDP port
S4 #1,2-ON, #3,4-OFF RT Port
CONTROL/
MODEM board(05P0702)
S5
#4-ON(RS422)
#4-OFF(C.Loop)
NAV port
RX board (05P0703) P1 ACTIVE
Connected
FAX-5 unit