9. “ROUTINE” or “BUSINESS” call cannot be made on DSC-60.
If Routine or Business call cannot be made with the error message Busy: RT” on
DSC-60, check frequency selected on the transceiver.
If calling can be made using frequencies other than 2182 kHz, the problem is due to
Priority setting.
When connected to FS-5000
Set the frequency of transceiver to a frequency other than 2182 kHz, and then make a
call.
When connected to FS-2550/1562
Set system setting channel:9928 to 1: Priority to remote unit on the transceiver.
Calling can also be made in 2182 kHz. Table below shows options on 9928.
Table 6.2.1 Setting of communication priority
System setting “9928 of FS-2550/1562 Priority
sequence
0:Priority to main unit 1: Priority to remote unit
1 DSC distress alarm DSC distress alarm
2 2182 kHz (RT)
Communication other than DSC
distress alarm
3
Communication other than DSC
distress alarm
Remote telephone
4 Remote telephone NBDP communication
5 NBDP communication 2182 kHz (RT)
6 Main unit wireless telephone Main unit wireless telephone
10. Frequency indicator of MF/HF transceiver blinks or blanks.
Synthesizer circuit is faulty. Change following board.
- FS-2550/1562
1) If blinking, Tx/Rx board (05P0526) is faulty.
- FS-5000
Before changing, turn off the REF OSC board [S1] switch to use a spare oscillator.
1) If Rx frequency indication is blank, Rx board (05P0348) is faulty
2) If Tx frequency indication is blank, EXC board (05P0349) is faulty.