5.1 Check list
5-4
Table 5.1.4
Check items Results
DSC-60
Registration of
MMSI
MMSI has been correctly registered?
Method of registering MMSI
“NMI SW” ON
Enter “652111”
Select MMSI
CLEAR
Enter MMSI.
System setting
The necessary system setting has been made?
Method of system setting
[SETUP]
Select “SYSTEM”
Enter652111
”Set”
Note) When FS-2550/1562 is fitted, set “REMOTE
STATION” to “ON” without fail.
Position display
Position data from GPS is entered?
SCAN setting and
scan operation
Set the scanning frequencies: SCAN/[SETUP].
It is recommended to use the international frequency as
ROUTINE frequency.
When “SCAN” key is pressed, the transceiver starts
scanning at the ROUTINE frequencies?
REMOTE
operation
When “REMOTE STATION” is set to “ON”, is it possible
to set the frequency, emission mode, and sound
volume of the transceiver and to make
communications?
Selftest
The results of the selftest are OK?
Program version
The program version has been checked?
To check the version:
During the selftest, press [1: RT] key five times while
holding down [FILE] key.
Connection to
printer
Is the result of the selftest printed? If the printing does
not work automatically, check “PRINT” setting in the
[SETUP] menu.
Power interlock
function
Turn off MF/HF transceiver and DSC-60.
When the DSC-60 is turned on, the MF/HF transceiver
comes on?