165
Function
Telemetry
Telemetry: The Drive Battery Electric Current
:KHQWKH6%6&HOHFWULFFXUUHQWVHQVRUVROGVHSDUDWHO\LVPRXQWHGRQWKHYHKLFOHWKH
HOHFWULFFXUUHQWYROWDJHDQGFRQVXPSWLRQFDSDFLW\RIWKHSRZHUEDWWHU\HWFFDQEHGLV
-
played.
* A drive battery electric current sensor must
be installed in the model car. Install and
connect the sensor following the sensor
instruction manual.
Telemetry
Current drive battery electric
current
Reset consumption capacity
The Speech function (ON/OFF)
The minimum and maximum
when powering ON are shown.
Alarm and vibrator ON/OFF and
type setting (The
arrow indicates
that an alarm is generated when
the electric current drops below
the set value and the
arrow indi-
cates that an alarm is generated
when the electric current exceeds
the set value.)
Current drive battery voltage
Reset consumption capacity
The Speech function (ON/OFF)
The minimum and maximum
when powering ON are shown.
Alarm and vibrator ON/OFF and
type setting (The
arrow indicates
that an alarm is generated when
the battery voltage drops below
the set value and the
arrow indi-
cates that an alarm is generated
when the battery voltage exceeds
the set value.)
Reset consumption capacity
The Speech function (ON/OFF)
The minimum and maximum
when powering ON are shown.
Alarm and vibrator ON/OFF and
type setting (The
arrow indicates
that an alarm is generated when
the battery capacity drops below
the set value and the
arrow
indicates that an alarm is gener-
ated when the battery capacity
exceeds the set value.)
-Upper side:
Current current/voltage/con-
sumption capacity display.
-Lower:
This is a display of the mini-
mum value/maximum value
of the measured current/volt-
age/consumption capacity
after turning on the transmit-
ter power.
* Tap the min/max display but-
ton to restart the measure-
ment.
c
t
i
o
n
nc
The minimum and maximum
Current drive battery capacity

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FUTABA 7PXR and is the answer not in the manual?

FUTABA 7PXR Specifications

General IconGeneral
Model7PXR
CategoryRemote Control
Channels7
Frequency2.4GHz
TelemetryYes
Model Memory40
DisplayColor LCD
Battery6.6V
CompatibilityS-FHSS
ReceiverR334SBS

Related product manuals