PART 2
AC GENERATORS
Page 28
Section 2.3
Troubleshooting Flow Charts
REPLACE
ROTOR ONLY
REPLACE
ROTOR ONLY
GOOD
PERFORM ROTOR
INSULATION
RESISTANCE TEST
TEST 9 – TEST
STATOR
BAD
GOOD
Problem 1 – Generator Produces Zero Voltage or Residual Voltage (Continued)
TEST 4 – PERFORM
FIXED EXCITATION /
ROTOR AMP DRAW
F
E
H
BAD
BAD
REPLACE
ROTOR AND
STATOR
BAD
TEST 10 –
TEST ROTOR
ASSEMBLY
TEST 10 –
TEST ROTOR
ASSEMBLY
TEST 9 – TEST
STATOR
GOOD
STOP TESTS
Problem 2 – Generator Produces Low Voltage at No-Load
LOW LOW
FREQUENCY
AND
VOLTAGE O.K.
FREQUENCY O.K.,
BUT VOLTAGE LOW
VOLTAGE O.K.,
BUT VOLTAGE IS
STLL LOW
GO TO “PROBLEM 1”
FLOW CHART - START
AT “TEST 4”
VOLTAGE AND FREQUENCY O.K.
TEST 11 – CHECK
AC OUTPUT
VOLTAGE
TEST 14 – ADJUST
VOLTAGE
REGULATOR
TEST 12 – CHECK
AC OUTPUT
FREQUENCY
TEST 13 - ADJUST
ENGINE
GOVERNOR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems CorePower and is the answer not in the manual?

Generac Power Systems CorePower Specifications

General IconGeneral
BrandGenerac Power Systems
ModelCorePower
CategoryPortable Generator
LanguageEnglish

Related product manuals