Page 4
Specifications
GENERATOR
Rated Voltage 240
Rated Maximum Load Current (Amps) at 240 Volts (LP)* 29.2
Main Circuit Breaker 30 Amp
Transfer Switch Load Center Circuits** 30A, 240V 1
30A, 240V 1
20A, 120V 3
15A, 120V 3
Phase 1
Number of Rotor Poles 2
Rated AC Frequency 60 Hz
Battery Requirement Group 26R, 12 Volts and 525 CCA Minimum
Weight (unit only in lbs.) 225
Enclosure Composite
Normal Operating Range: This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 °F (-29 °C) to 122 °F. (50 °C). For areas
where temperatures fall below 32 °F (0 °C), a cold weather kit is highly recommended. When operated above 77º F (25º C) there may be a decrease in engine
power. (Please reference the engine specifications section).
These generators are rated in accordance with UL2200, Safety Standard for Stationary Engine Generator Assemblies; and CSA-C22.2 No. 100-04 Standard for
Motors and Generators.
* Natural Gas ratings will depend on specific fuel Btu content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the transfer switch.
ENGINE
Type of Engine OHV-432
Number of Cylinders 1
Rated Horsepower @ 3,600 rpm* 14.8
Displacement 432cc
Cylinder Block Aluminum w/Cast Iron Sleeve
Valve Arrangement Overhead Valves
Ignition System Solid-state w/Magneto
Recommended Spark Plug RC12YC
Spark Plug Gap 0.76 mm (0.030 inch)
Compression Ratio 8.2:1
Starter 12 VDC
Oil Capacity Including Filter Approx. 1.1 Qts (1.0L)
Recommended Oil Filter Part # 0H9039
Recommended Air Filter Part # 0H6104
Operating RPM 3,600
* Engine power is subject to and limited by such factors as fuel Btu content, ambient temperature and altitude. Engine power decreases about 3.5 percent for each
1,000 feet above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F) ambient temperature.
Caution: Specifications are for reference only, for actual installations always use the most recent version available online.
These specifications are subject to change without notice.