EasyManuals Logo
Home>Generac Power Systems>Portable Generator>CorePower

Generac Power Systems CorePower User Manual

Generac Power Systems CorePower
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
ENGINE/DC CONTROL
PART 4
Section 4.4
Troubleshooting Flowcharts
Page 57
VERIFY UTILITY
SOURCE IS “OFF”
TEST 52 – CHECK
POSITION OF
AUTO-OFF-MANUAL
SWITCH
TEST 53 – TRY A
MANUAL START
ON
OFF
SWITCH IS “OFF”
SWITCH IS
IN “AUTO”
ENGINE DOES
NOT CRANK
ENGINE
CRANKS
SET TO “AUTO” -
RETEST
TURN “OFF” -
RETEST
GO TO PROBLEM 21
REPLACE CONTROLLER
ASSEMBLY
Problem 20 – Engine Will Not Crank When Utility Power Source Fails
RECHARGE /
REPLACE
NOTE: If a starting problem is encountered,
the engine itself should be thoroughly
checked to eliminate it as the cause of starting
difficulty. It is a good practice to check the
engine for freedom of rotation by removing the
spark plugs and turning the crankshaft over
slowly by hand, to be sure it rotates freely.
WARNING: DO NOT ROTATE
ENGINE WITH ELECTRIC STARTER
WITH SPARK PLUGS REMOVED.
ARCING AT THE PLUG ENDS MAY
IGNITE THE LP OR NG VAPOR
EXITING THE SPARK PLUG HOLE.
TEST 56 – CHECK
BATTERY
TEST 55 – CHECK
7.5 AMP FUSE
TEST 59 – TEST
STARTER MOTOR
TEST 58 –
CHECK STARTER
CONTACTOR
BAD
BAD
BAD
BAD
BAD
GOOD
GOOD
GOOD
GOOD
GOOD
REPLACE
REPLACE
Problem 21 – Engine Will Not Crank When AUTO-OFF-MANUAL Switch is Set to “MANUAL
REPLACE
CONTROLLER
ASSEMBLY
TEST 57 – CHECK
WIRE 56 VOLTAGE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems CorePower and is the answer not in the manual?

Generac Power Systems CorePower Specifications

General IconGeneral
BrandGenerac Power Systems
ModelCorePower
CategoryPortable Generator
LanguageEnglish

Related product manuals