Setup
The charger is factory preseted.
Use this section if you need to restore the settings:
To open settings:
On PROGRAM SELECT main screen press Batt type/Stop button several times,
to the moment, when screen will Settings section;
Press Start/Enter to open settings menu.
Use Dec and Inc buttons to choose parameters and Start/Enter to select.
Select Safety timer and press Start/Enter button.
Use Dec/Inc buttons to change it to OFF. Press Start/Enter button until stop
switcher blinking.
Select Capacity cut-off and press Start/Enter button.
Use Dec/Inc buttons to change it to OFF. Press Start/Enter button until stop
switcher blinking.
Press Batt type/Stop button to exit from settings section.
On PROGRAM SELECT main screen select Lithium battery section and press
Start/Enter button. Set these parameters:
AUTO value, that denes battery cells number (S) automatically.
Charge current: 10,0 A.
Other settings not should be specied.