G5 – Owner‘s Manual | 127
Threshold: 127=0dB, 64=-6dB, 32=-12dB, 16=-18dB, 8=-24dB, 4=-30dB, 2=-
36dB 0=-Inf
Ratio: 127=1/128, 126=2/128 (1/64), 125=3/128, … 64=64/128 (1/2), … 0=1/1
Request Input / Gain Reduction / Output levels (see below for Response
message)
Note 1: 14bit precision when using NRPN MSB+LSB value, 1 Hz step
20.3.6 COMPRESSOR INPUT / GAIN REDUCTION / OUTPUT LEVELS
RESPONSE PACKET DESCRIPTION
Packet Type = "CR" (Compressor Response)
Compressor channel ID (see below)
Compressor reduction value left
Compressor reduction value right
CMP ID is the ID of Compressor channel (0 = Master, 1 = Monitor, 2 = Headphone, "rr" for drum channels)
INP, OUT are values of peak level in dB range from 0 till 70 as follows:
70 = 0dB, 69 = -1dB, 68 = -2dB (1dB steps) ... 64= -6dB ... 0 = -infinite
GR is a value of reduction level in dB range from 0 till 70 as follows:
70 = -70dB, 69 = -69dB, 68 = -68dB (-1dB steps) … 20= - 20dB … 0 = no compression