42
Fryer Operation
GBF-50 Fryer
4.01.7.3 AUTO-COOL Feature
4.01.7.4 BOIL OUT Mode
Exit AUTO‐COOL same as COOL ... press the [CLEAR] key, then press [<4] to exit
‐ OR ‐
Press [CLEAR] again to continue COOL Mode.
Upon exit, the temperature setpoint will return to the previous active value and
fryer enters PREHEAT mode until temperature is reached. A STIR OIL alarm is
issued when setpoint is reached, as described in Section 4.01.2.
+
When AUTO‐COOL feature is set to [ON], the fryer will automatically enter COOL mode if no cook cycles have been
started within the time specified by the [AUTOCOOL TIME] setting in User Settings, see Section 4.01.8.
Factory‐default: [AUTOCOOL] is OFF • [AUTOCOOL TIME] = 30 ... setting can be edited in a range of 1 to 510 mins.
IMPORTANT!
After BOIL OUT MODE is completed, the controller automatically resets the temperature setpoint to 50°F. It must
be reset to a proper cooking temperature before the fryer will heat cooking oil for normal operation.
Fryer must be properly drained, rinsed and prepared for cooking after a Boil Out cycle. See Section 6, Cleaning.
After fryer has been properly prepared for a boil‐out cycle, press the [BOIL] key while
controller is in PREHEAT state to start BOIL OUT Mode.
Temperature and time change to the BOIL TEMP and BOIL OUT TIME, respectively, as
specified in User Settings, see Section 4.01.8 fryer begins heating the boil out solution.
Factory‐defaults:
BOIL TEMP = 200°F ... can be set in a range of 185° to 208°F.
BOIL OUT TIME = 30 minutes ... can be set in a range of 1 to 45 mins.