43
Fryer Operation
GBF-50 Fryer
4.01.8 User Settings
NAME DESCRIPTION RANGE DEFAULT
TEMP SCALE Temperature unit of measure °F or °C °F
FORCE FILTER
When ON, forces operators to filter oil after the number of
cook cycles set in
FILTER COUNT are completed ... locksout
fryer until filtering complete.
ON OFF ON
FORCE FILTER
SNOOZE
When ON, allows (1) additional cook cycle after FILTER COUNT is
exceeded, when FORCE FILTER is ON.
ON OFF OFF
FILTER COUNT Number of cook cycles before filtering is required. 1 to 20 4
GUARD BAND
Cooking not allowed if oil temperature is outside of the
setpoint by amount of guard band
1 to 990 900
MAX SETPOINT Maximum oil setpoint allowed by controller. 32°F to 375°F 350°
AUTOCOOL After a specified amount of time, unit will enter COOL mode. ON OFF OFF
AUTOCOOL TIME
(MINUTES)
When AUTOCOOL is ON, fryer automatically enters COOL mode
after unit is idle for this amount of time.
1 to 510 minutes 30
AUDIBLE ALARM
(SECONDS)
Duration of the audible alarm in seconds, automatically silences
after this amount of time..
5 to 120 seconds 10
COOL TEMP Temperature setting for COOL mode 200°F to 350°F 275°F
BOIL TEMP Temperature setting for the BOIL OUT cycle 185°F to 208°F 200°F
FILTER RESET A temperature that resets fryer to exit FILTER MODE. 200°F to 325°F 290°F
BOIL OUT TIME Time (in minutes) for the BOIL OUT cleaning cycle 1 to 45 minutes 30
STIR ALARM
ENABLE
If ON, sounds the STIR ALARM at specified % of cook cycle
completion.
ON OFF ON
STIR ALARM %
When STIR ALARM is ON, the alarm sounds after this percent
[%] of cooking cycle has elapsed.
10% to 90% 62%
KEY BEEP ENABLE If ON, an audible sound is generated with each keystroke. ON OFF OFF
Press the
[TIME] key
9999
To view current user settings, use keys [4] & [6] (left/right) to scroll settings
and display each in the upper display.
To exit User Settings menu, press the [CLEAR] key.
• To edit the displayed setting, press the [EDIT]key.
• Use up/down keys [2 & 8] to change the value ... Press
[EDIT] again to save new setting.
Press the
[START] key
NOTE:
The message “TOO LOW” or “TOO
HIGH” is displayed if an entered
value is outside the allowable range
for a setting, which will result in a
controller error.
Access User Settings menu and edit settings as follows:
Enter on
keypad
Continued on Next Page

Table of Contents