5. Enter the control network IP address and other network settings.
6. For SNMP Conguration, enter the IP address of the NetCentral server PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
7. Click OK to save settings and close.
8. In Storage Utility click View | Refresh.
Next, bind disk modules.
Binding disk modules - Basic K2 SAN
Prerequisites for the K2 RAID chassis are as follows:
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on
Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:
Fibre channel cable(s) connected
Power on
NOTE: Binding destroys all user data on the disks.
1. If you have not already done so, launch Storage Utility from the K2Cong application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.
3. In the Storage Utility main window, identify bound RANKs and unbound disks by their placement
in the hierarchy of the tree view. In the following illustration, disk numbers are represented by
XX.
138 K2 SAN Installation and Service Manual 02 February 2012
Conguring and licensing the K2 SAN

Table of Contents