Powering on/off a SAN client
As long as the K2 SAN remains operational, you can use the standard power on and power off
procedures appropriate for the SAN client. When a SAN client goes ofine or comes online it does
not disrupt the K2 SAN.
However, if you are powering down or otherwise taking the K2 SAN itself out of service, you must
follow the correct SAN power down procedure. You must rst stop all media access on your SAN
clients to ensure that they do not cause error conditions. You can power off the SAN clients or take
them ofine using the K2Cong application.
When powering up the K2 SAN, power on the SAN clients last so that they can verify their media
storage as part of their start up processes.
Taking a SAN client offline
1. Stop all media operations on the device. This includes, play, record, and transfer operations.
2. Shut down the SAN client.