EasyManuals Logo

GRASS VALLEY K2 Installation And Service Manual

GRASS VALLEY K2
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #242 background imageLoading...
Page #242 background image
Powering on/off a SAN client
As long as the K2 SAN remains operational, you can use the standard power on and power off
procedures appropriate for the SAN client. When a SAN client goes ofine or comes online it does
not disrupt the K2 SAN.
However, if you are powering down or otherwise taking the K2 SAN itself out of service, you must
follow the correct SAN power down procedure. You must rst stop all media access on your SAN
clients to ensure that they do not cause error conditions. You can power off the SAN clients or take
them ofine using the K2Cong application.
When powering up the K2 SAN, power on the SAN clients last so that they can verify their media
storage as part of their start up processes.
Taking a SAN client offline
1. Stop all media operations on the device. This includes, play, record, and transfer operations.
2. Shut down the SAN client.
242 K2 SAN Installation and Service Manual 02 February 2012
Conguring clients on the K2 SAN

Table of Contents

Other manuals for GRASS VALLEY K2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GRASS VALLEY K2 and is the answer not in the manual?

GRASS VALLEY K2 Specifications

General IconGeneral
BrandGRASS VALLEY
ModelK2
CategoryStorage
LanguageEnglish