On a RAID chassis with two controllers, if the replacement controllers rmware is not the same
as the rmware on the redundant (currently installed) controller, the rmware on the replacement
controller is automatically upgraded or downgraded to match the current system level rmware.
NOTE: Refer to the Instruction Manual for your RAID storage chassis for procedures on
removing and replacing the RAID controller module.
1. Open the Storage Utility.
2. Expand the tree view to display the controllers.
3. Select the controller and check its status, then proceed as follows:
If the faulty controller reports as disabled, proceed to the next step in this procedure.
If the faulty controller reports as online, right-click the controller icon in the tree view, and
select Advanced | Disable Controller 0 or Disable Controller 1, then click OK to continue.
The RAID controller is disabled. You can check controller status in the Storage Utility. You may
need to refresh the display.
NOTE: If you accidentally disable the wrong controller, you can enable it again by removing
it and then replacing it in the chassis.
4. Remove and replace the disabled RAID controller module.
Refer to procedures in the Instruction Manual for your RAID storage chassis.
5. On inserting the replacement RAID controller, it initializes and is automatically enabled to
become the backup RAID controller.
Configuring RAID chassis network and SNMP settings
Through Storage Utility you can congure the following settings on a RAID chassis:
IP address
Subnet mask
Gateway Address
SNMP trap destinations
Whenever you modify control network settings or FTP/streaming network settings on any device,
you must then redeploy the hosts le if that is your name resolution mechanism.
For the 10G RAID chassis, network and SNMP settings are set and stored on the RAID controller.
Therefore, if the RAID chassis has two controllers, each controller must be congured separately,
as in the following procedure.
1. In the K2Cong application tree view, open the node for a K2 Media Server and select the File
System Server node to open its property page. On the property page click Launch Storage Utility.
Storage Utility opens. You can now congure the network settings on the controller connected
to the selected K2 Media Server.
02 February 2012 K2 SAN Installation and Service Manual 331
Administering and maintaining the K2 SAN