The restart of the K2 Media Server after it is congured is complete
This task is required for NAS server functionality.
1. Verify that the K2 Media Server has restarted by opening the MS-DOS command prompt and
use the ping command.
2. In the K2Cong application tree view, under the K2 Media Server select the File System Server
node.
The File System Server Conguration page appears.
3. Click Check and verify that the V: drive is shared.
The K2 Nearline SAN conguration is complete.
Configuring the redundant nearline K2 SAN
Work through the topics in this section sequentially to congure a redundant nearline (Tier 3) K2
SAN.
Prerequisites for initial configuration - Nearline K2 SAN
Before beginning your initial conguration, make sure the devices of the K2 SAN meet the following
prerequisites.
Control point PC
Ethernet cable connected
Control Point software installed
Control network IP address assigned
Network communication over the control network with all other K2 devices
Power on
Ethernet switch
Ethernet cables connected
Control network IP address assigned
VLANs set up
Trunks set up
Power on
K2 Media Server
Ethernet cables connected
Fibre Channel cable connected
Redundant servers connected by serial cable
Software installed, as from the factory, including QuickTime 7