EasyManua.ls Logo

GRASS VALLEY K2 - Fibre Channel Connected Clients (Redundant Fsms)

GRASS VALLEY K2
366 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fibre Channel connected clients (redundant FSMs)
RAID Storage
GigE Fabric
K2 SAN-attached client systemsK2 Media Servers
Fibre Channel Fabric
Control Point PC
POWER
SERVICE
K2
RAIDSTORAGE
!!
POWER
SERVICE
K2
RAIDSTORAGE
!!
POWER
SERVICE
K2
RAIDSTORAGE
!!
POWER
SERVICE
K2
RAIDSTORAGE
!!
!
K2
MEDIASERVER
K2
MEDIASERVER
!
K2
MEDIASERVER
!
K2
MEDIASERVER
K2
MEDIASERVER
K2
MEDIASERVER
Key to illustrated cable paths:
Fibre Channel carrying real-time media
Gigabit Ethernet carrying traffic that is not
real-time media
A black/gray pair denotes redundant cables
This system differs from the iSCSI extended system as follows:
K2 SAN-attached client systems have a Fibre Channel card installed and are connected directly
to the Fibre Channel Fabric. This replaces the iSCSI layer.
Because there is no iSCSI, there is no need for multiple K2 Media Servers to act as iSCSI bridges,
reducing the total number of K2 Media Servers required.
There is a RAID chassis dedicated for le system metadata.
The FSM K2 Media Servers read/write data over Fibre Channel only to the metadata RAID
chassis.
The FSM K2 Media Servers must "see" (be on the same Fibre Channel fabric with) the media
RAID, even though they do not read/write data to the media RAID.
Guidelines for this system are as follows:
When adding a K2 SAN-attached client system in K2Cong, set the Storage access option to
Fibre Channel.
When conguring the system in K2Cong, select the Server redundancy option.
344 K2 SAN Installation and Service Manual 02 February 2012
Custom K2 SAN systems

Table of Contents

Other manuals for GRASS VALLEY K2