3. In the Storage Utility main window, identify bound RANKs and unbound disks by their placement
in the hierarchy of the tree view. In the following illustration, disk numbers are represented by
XX.
Redundant systems store le system metadata les and journal les on the primary RAID chassis.
The rst six disk slots in the chassis are dedicated for metadata/journal les. In the rst ve slots
are ve metadata/journal disks. The sixth slot is lled with a blank. Two disks are bound as a
RAID 1 RANK for metadata storage and two disks are bound as a RAID 1 RANK for journal
storage. The fth disk is bound as a Hot Spare for the other four metadata/journal disks. The
remaining six disks in the primary RAID chassis and all disks in Expansion chassis are for media
storage. Media storage disks are bound as RAID 5 or RAID 6 in RANKs consisting of six disks
each.
View disk properties and identify the four disks you will use for the metadata/journal RAID 1
RANKs, the one metadata/journal Hot Spare disk, any other disks that you intend to use for Hot
Spares, and the remainder of the disks that are available for media storage. Make sure you select
disks appropriately as you bind disks in the remainder of this procedure.
02 February 2012 K2 SAN Installation and Service Manual 163