5. Enter the control network IP address and other network settings.
6. For SNMP Conguration, enter the IP address of the NetCentral server PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
7. For the RAID chassis with two controllers, in the Controller Slot Number eld enter 1 and then
press Enter.
The settings from controller 1 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
8. Repeat the previous steps to congure controller 1.
9. Click OK to save settings and close.
10. In Storage Utility click View | Refresh.
Next, bind disk modules.
Binding disk modules - Nearline K2 SAN
Prerequisites for the K2 RAID chassis are as follows:
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on
Prerequisites for the optional K2 RAID Expansion chassis (if present) are as follows:
Fibre channel cable(s) connected
Power on
NOTE: Binding destroys all user data on the disks.
1. If you have not already done so, launch Storage Utility from the K2Cong application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.