Sensors group
Short name: Sens
Maximum JHPU oil temperature, before an alarm
condition. Set to zero to disable the oil temperature
Enables the JPHU oil level sender
Enables the bearing oil temperature switch detection
rev
PPR
The number of pulses per rev the jet RPM senor will be
triggered per revolution, Set to zero to disable the jet
Stagd
Enables staggered pulses on the jet RPM sensor, which
allows direction detection. This only works when the jet
Backup group
Short name: Bkp
Overrides the automatic backup str kp control value. Set
to zero to use automatic value
Overrides the automatic backup rev kp control value.
Set to zero to use automatic value
Overrides the automatic backup str ki control value. Set
to zero to use automatic value
Overrides the automatic backup rev ki control value. Set
to zero to use automatic value
The backup engine dmd interface mode:
Vo - Voltage
Cu - Current
ID - Increment/Decrement
Pl - PWM voltage
Pd - PWM open drain
Pp - PWM open drain w/pullup
The backup eng dmd high value
The backup eng dmd low value
The backup eng dmd A value
The backup eng dmd B value
Inverts the engine dmd output