HTX30 Product Manual
Appendix
8-51
Save and reload group
Short name: Save / Relod
Name
SCP text
Description
Min
Max
Default
Units
Access
Load factory values
LoadF
Copies the factory parameters to the user space, this
will default all user settings
D
Save to ship
Save
Sets the ship defaults, used at the end of commissioning
D
Save to Character
Factory
SaveC
Sets the factory defaults of the character rom
F
Save Rom Defs to
Character Factory
SaveR
Sets the factory defaults of the character rom to the
hard coded Rom defaults, i.e total reset
F
Clear Defaults Alarm
Clear / Defs
Clears the Default Alarm orginating from the Character
Rom
D
Commissioning group
Short name: Comsn
Name
SCP text
Description
Min
Max
Default
Units
Access
Drive port
DPort
Unconditionally drives the steering nozzle to port, no
deadband compensation
C
Drive stbd
DStbd
Unconditionally drives the steering nozzle to stbd, no
deadband compensation
C
Drive up
DUp
Unconditionally drives the reverse duct up, no
deadband compensation
C
Drive down
DDown
Unconditionally drives the reverse duct down, no
deadband compensation
C
Str raw Fbk
SRaw
Steering raw feedback, no scaling
C
Rev raw Fbk
RRaw
Reverse raw feedback, no scaling
C
Rpm logic state
Rpm
Indicates the current logic state of the RPM sender
C

Table of Contents