Port waterjet has gone unavailable The test aborted when the port waterjet became unavailable
The JETanchor Mouseboat has control of all waterjets and
engines that are available for remote (normal) control
Determine why the waterjet became unavailable, resolve any
issues, then rerun the test
SCP has gone into backup mode The test aborted when backup mode was engaged
The backup jogstick of the station control panel (SCP) that is in
control now has control
Ensure that all propulsion lines are in normal mode, then rerun
the test
SCP has gone into setup mode
The test aborted because the blue ARROW system was placed in
setup mode
The JETanchor Mouseboat has control of all waterjets and
engines that are available for remote (normal) control
Ensure that all normal blue ARROW set up has been completed,
then rerun the test
Starboard waterjet has gone
unavailable
The test aborted when the starboard waterjet became
unavailable
The JETanchor Mouseboat has control of all waterjets and
engines that are available for remote (normal) control
Determine why the waterjet became unavailable, resolve any
issues, then rerun the test
Stbd engine RPM is no longer
following up
The test aborted because starboard engine rpm is not
responding to throttle demand
The JETanchor Mouseboat has control of all waterjets and
engines that are available for remote (normal) control
Locate and resolve the throttle demand fault, then rerun the
test
Stbd gearbox has gone into
backflush
The test aborted because the starboard gearbox has been
placed in backflush gear
The JETanchor Mouseboat has control of the port propulsion
line
Ensure all gearboxes are in drive, then rerun the test
Stbd gearbox has gone into neutral The test aborted because the starboard gearbox has been
placed in neutral
The JETanchor Mouseboat has control of the port propulsion
line
Ensure all gearboxes are in drive, then rerun the test
Stbd steering has gone into backup
The test aborted because the starboard propulsion line has
been placed in backup mode
The backup jogstick of the station control panel (SCP) that is in
control now has control
Ensure that all propulsion lines are in normal mode, then rerun
the test