4 - Sprayer set-up
34
Electrical connections
Installing the control unit supports
Position the control units in the most suitable place in the tractor cab.
The best position is to the right of the driver's seat.
The support (A) supplied is drilled with holes spaced at 100 and 120mm
and is suitable for most tractors. Tapped fixing holes are sometimes
concealed inside the front post protector. See the tractor's user manual
for the fixings in the cab.
Three tubes (B) are supplied. You can use 1, 2 or all 3 of them. They can
be bent and shortened. A spacer (C) is also supplied to allow for other
types of fitting. It is up to you to choose the best solution for your tractor.
The tube (B) is adjustable, so that, when correctly oriented, all the units
will be in line.
Electrical supply
Power required: 12V DC. Always check the polarity! To ensure sufficient
power and correct operation of the electrical equipment, use the
correct size of cables and fuses. The plugs supplied comply with the
most recent standards for tractors. If they do not fit, remove them and
connect the wires directly to the socket on the tractor.
The number and type of plugs can vary for the same sprayer, depending
on its equipment.
CIGARETTE LIGHTER
The spraying control unit requires:
2.5mm² cable, 10 Amp fuse
The hydraulic control unit requires:
4.0mm² cable, 16 Amp fuse
ROAD SIGNALLING SOCKET
100 -120mm
A
B
C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi RANGER 2500 TR2 and is the answer not in the manual?

Hardi RANGER 2500 TR2 Specifications

General IconGeneral
BrandHardi
ModelRANGER 2500 TR2
CategoryFarm Equipment
LanguageEnglish

Related product manuals