3/6/08 888-2463-001 2-29
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Diamond Series™
2.10.3 Remote Power Metering, J3
Each analog metering output will provide 0-4Vdc output into a 400 ohm load. By
squaring this voltage in the remote control equipment, a voltage proportional to the RF
power it represents can be obtained. The connections for J3 are listed in Table 2-4.
2.11 Remote GUI Description and Setup
Refer to the DiamondCD™ Software Manual for information on Loading or updating
any software in the transmitter, including the GUI, Remote GUI or ISP applications.
Table 2-4 J3, System I/O Board, Remote Power Metering
Connection Metered Parameter
J3-1 Total Forward Output Power
J3-2 Total Reflected Output Power
J3-3 PA Cabinet 1 Forward Power Output
J3-4 PA Cabinet 1 Reflected Power Output
J3-5 PA Cabinet 2 Forward Power Output
J3-6 PA Cabinet 2 Reflected Power Output
J3-7 PA Cabinet 3 Forward Power Output
J3-8 PA Cabinet 3 Reflected Power Output
J3-9 PA Cabinet 4 Forward Power Output
J3-10 PA Cabinet 4 Reflected Power Output
J3-11 PA Cabinet 5 Forward Power Output
J3-12 PA Cabinet 5 Reflected Power Output
J3-13 thru J3-16 Spare
J3-17 thru J3-19 No Connection
J3-20 thru J3-35 Transmitter Ground
J3-36 and J3-37 No Connection