57
MP60, MP60DP
CAN INTERFACE DESCRIPTION
ValuesAttr.FormatNameSub
index
Index
(hex)
2110 1 Activate parameter
set
unsigned16 rw 6600: Factory settings
6601: Parameter set 1
6602: Parameter set 2
6603: Parameter set 3
6604: Parameter set 4
2111 1 Save parameter set unsigned16 rw see above
Display adaptation
2120 1 Decimal point
position
unsigned16 rw 0..5
2121 1 Step size unsigned16 rw 110: 1
111: 2
112: 5
113: 10
114: 20
115: 50
116: 100
117: 200
118: 500
119: 1000
Transducer
2122 1 Physical unit unsigned16 rw 1603: g
1604: kg
1605: T
1606: kT
1607: TON
1608: lb
1609: oz
1610: N
1611: kN
1619: μm
1620: mm
1621: cm
1622: m
1623: inch
1624: Nm
1625: kNm
1626: FTLB
1627: INLB
1628: μm/m
1629: m/s
1630: m/s
2
1631: %
1632: ‰
1633: ppm
1636: MN
1637: NoUnit
1641: Hz
1642: kHz
1643: 1/s
1644: rpm
1645: rpm
1646: Imp
1647: kImp
1648: deg
1649: rad
1650: rad/s
1651: km/h
1652: mph
1653: ft/s
1654: inoz
1655: Ncm
1656: l/h
1657: l/mi