Page 6-10 Work Instruction Wizard
PLT-01067, Version: A.7 July 2017
6.2 MIFARE Classic Work Instructions
6.2.1 MIFARE Classic: HID Access Application
This section covers the Work Instruction for MIFARE Classic, with HID Access Application encoding.
1. Select the MIFARE Classic technology type, and click OK.
2. The Work Instruction Wizard opens to allow you to configure the Work Instruction for MIFARE
Classic. Click Next.
3. Select Data Format: You can make selections from the following. When complete click Next.
Note: For this example, a Write/HID Application/SE configuration is selected.
Field Description
Instruction Type Read, Write, Roll Card Authentication Key, or Move Genuine SO Sector
Data Type HID Access Application, or Custom
Options Overwrite Existing Credential: Allows the iCLASS SE Encoder to write over an
application that has already been recorded in the Work Order database.
Enable User PIN Entry (available with SR (HID Access Application and SO only)
Credential Type SE (SO only), SR (HID Access Application and SO), or HID Access Application.
Format: Select a Format from the list.

Table of Contents