Page 6-18 Work Instruction Wizard
PLT-01067, Version: A.7 July 2017
6.3 MIFARE DESFire EV1 Work Instructions
6.3.1 MIFARE DESFire EV1: HID Access Application
This section covers the Work Instruction for MIFARE DESFire EV1, with HID Access Application
encoding.
1. Select the MIFARE DESFire EV1 technology type. Click OK.
2. The Work Instruction Wizard opens to allow you to configure the Work Instruction for MIFARE
DESFire EV1. Click Next.
3. Select Data Format: You can make selections from the following. When complete click Next.
Note: For this example, a Write/HID Access Application configuration is selected.
Field Description
Instruction Type Read, Write, or Roll Card Authentication Key
Data Type HID Access Application, or Custom
Options Overwrite Existing Credential: Allows the iCLASS SE Encoder to write over an
application that has already been recorded in the Work Order database.
Enable User PIN Entry (available with SR (HID Access Application and SO only)
Credential Type SE (SO only), SR (HID Access Application and SO), or HID Access Application.
Format: Select a Format from the list.