Table 6-1 Temperature Measurement Parameters Descripons
Parameter Descripon
Enable Temperature Detecon When enabling the funcon, the device will authencate the
permissions and at the same me take the temperature. When
disabling the device, the device will authencate the
permissions only.
Over-Temperature Alarm
Threshold(Max./Min.)
Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured parameters,
an alarm will be triggered. By default, the value is 37.3°.
Temperature Compensaon If the measured temperature is higher/lower than the actual
object's temperature, you can set the compensaon
temperature here. Available range: -99 °C to 99 °C
Door Not Open When
Temperature is Abnormal
When enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the funcon is enabled.
Temperature Measurement
Only
When enabling the funcon, the device will not authencate the
permissions, but only take the temperature. When disabling the
funcon, the device will authencate the permissions and at the
same
me take the temperature.
Unit Select a temperature unit according to your preference.
Measurement Area
Calibraon/Measure Area
Sengs
Congure the temperature measurement area and the
correcon parameters.
Black Body Sengs When enabling the funcon, you can congure the black bodys
parameters, including the distance, temperature, and emissivity.
Note
When measuring the black body, make sure the device's camera
faces the black body, and there should be no other objects
between the black body and the camera. Once the sample black
body is calibrated, make sure the measurement area of the
measuring black body should be the same as the calibrated one,
or the temperature measurement may be failed.
Face Recognion Terminal User Manual
36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K1TA70MI-T and is the answer not in the manual?

HIKVISION DS-K1TA70MI-T Specifications

General IconGeneral
BrandHIKVISION
ModelDS-K1TA70MI-T
CategoryIP Access Controllers
LanguageEnglish

Related product manuals