8.5 Message List
122
Message ([ ] = optional) Data Contents
( ) = response data
Description Ref
page
Comparator
:CALCulate:LIMit:BEEPer
OFF/ HL/ IN/ BOTH1
/ BOTH2
Sets the comparator judgment beeper
setting
135
:CALCulate:LIMit:BEEPer?
OFF/ HL/ IN/ BOTH1
/ BOTH2
Queries the comparator judgment
beeper setting
135
:CALCulate:LIMit:RESistance:MODE
HL/ REF Sets the resistance comparator exe-
cution mode setting
135
:CALCulate:LIMit:RESistance:MODE?
HL/ REF Queries the resistance comparator
execution mode setting
135
:CALCulate:LIMit:VOLTage:MODE
HL/ REF Sets the voltage comparator execu-
tion mode setting
135
:CALCulate:LIMit:VOLTage:MODE?
HL/ REF Queries the voltage comparator exe-
cution mode setting
135
:CALCulate:LIMit:RESistance:UPPer
<Upper threshold> Sets the resistance comparator upper
threshold setting
136
:CALCulate:LIMit:RESistance:UPPer?
<Upper threshold> Queries the resistance comparator
upper threshold setting
136
:CALCulate:LIMit:VOLTage:UPPer
<Upper threshold> Sets the voltage comparator upper
threshold setting
136
:CALCulate:LIMit:VOLTage:UPPer?
<Upper threshold> Queries the voltage comparator upper
threshold setting
136
:CALCulate:LIMit:RESistance:LOWer
<Lower threshold> Sets the resistance comparator lower
threshold setting
137
:CALCulate:LIMit:RESistance:LOWer?
<Lower threshold> Queries the resistance comparator
lower threshold setting
137
:CALCulate:LIMit:VOLTage:LOWer
<Lower threshold> Sets the voltage comparator lower
threshold setting
137
:CALCulate:LIMit:VOLTage:LOWer?
<Lower threshold> Queries the voltage comparator lower
threshold setting
137
:CALCulate:LIMit:RESistance:REFerence
<Reference value> Sets the resistance comparator refer-
ence value
138
:CALCulate:LIMit:RESistance:REFerence?
<Reference value> Queries the resistance comparator
reference value
138
:CALCulate:LIMit:VOLTage:REFerence
<Reference value> Sets the voltage comparator refer-
ence value
138
:CALCulate:LIMit:VOLTage:REFerence?
<Reference value> Queries the voltage comparator refer-
ence value
138
:CALCulate:LIMit:RESistance:PERCent
<Tolerance (%)> Sets the resistance comparator deci-
sion tolerance setting
139
:CALCulate:LIMit:RESistance:PERCent?
<Tolerance (%)> Queries the resistance comparator
decision tolerance setting
139
:CALCulate:LIMit:VOLTage:PERCent
<Tolerance (%)> Sets the voltage comparator decision
Tolerance setting
139
:CALCulate:LIMit:VOLTage:PERCent?
<Tolerance (%)> Queries the voltage comparator deci-
sion tolerance setting
139
:CALCulate:LIMit:RESistance:RESult?
HI/ IN/ LO/ OFF/ ERR Queries resistance comparator judg-
ment results
140
:CALCulate:LIMit:VOLTage:RESult?
HI/ IN/ LO/ OFF/ ERR Queries voltage comparator judgment
results
140
:CALCulate:LIMit:ABS
1/0/ON/OFF Sets the comparator absolute value
judgment function
140
:CALCulate:LIMit:ABS?
ON/OFF Queries the comparator absolute val-
ue judgment function
140