● Long-term Shutdown 7-42
6
When the predetermined period of time elapses, the following
operating guidance appears.
Circulation control
2011.07.07 12:45
Proc. status:
Function:Process prior to
long-term shutdown.
Proc. time: Approx. 6 minutes.
Operating guide
Place the ink reservoir tube
connection block back into
position. When ready, press
[Start/Continue].
Status:Service
Start/
Continue
Abort
Ink drainage
Ink drainage
System-clean
System-clean
7
Mount the tube connection block on the ink reservoir, and then
mount it into the printer.
¡
Be careful not to break the tube when mounting it into the printer.
8
Repeat the operations of 2 to 7 .
(Perform the ink drainage to cleaning of the circulation system twice in total.)
9
Mount the nozzle rubber seal.
¡
Mount the "nozzle rubber seal" between the charge electrode and the
orifice plate.
1. Before installing the nozzle rubber seal, be sure to thoroughly clean
it with the makeup ink.
2. When installing the nozzle rubber seal, exercise care not to deform
the charge electrode.
Notice
The procedure to be performed prior to long-term shutdown is now completed.
The circulation system is now charged with the makeup ink.
When starting up the printer after a long-term shutdown, be sure to perform the
"7.15.2 Startup process to be performed after long-term shutdown."