Communication Timing 6-47
T1 Maximum time (ms)
10
N + 25
(N: Number of
communication items)
5
10
20
20
M+10
(M: number of
communication
characters)
Conditions
The print message
transfer ACK
condition is t=fixed.
The print message
transfer ACK
condition is t=async.
Print specifications
Print format
Overall column setup
Transmission type
Print description
Print data recall
Print conditions
User pattern
character
No.
1
2
3
4
5
6
Remarks
1
1
6.5.2 Response Time
(1) Time interval (T1) between external device communication and IJ
printer response
External device
IJ printer
ENQ
ACK
STX ETX
ACK
………
T0
T1
Baud rate (bps)
150 to 1200
2400 to 38400
T0 Maximum T0 time (ms)
5
1
*1 For "t=fixed" and "t=async.", see Section 6.2.1, "Setting Communication
Environment ".