EasyManuals Logo

Honeywell MetroSelect Eclipse MS 5145 User Manual

Honeywell MetroSelect Eclipse MS 5145
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
9–3
Codabar Formatting
³ 1 0 7 7 1 7
Transmit Codabar Start/Stop Characters
Transmits Codabar’s Start/stop characters before
and after each bar code.
³ 1 0 7 7 0 7
* Do Not Transmit Codabar Start/Stop
³ 1 1 5 1 0 0
* Normal Codabar Start/Stop Characters
³ 1 1 5 1 1 0
Enable Transmit Codabar Start/Stop
Characters as Lower Case Characters
³ 1 0 7 7 1 6
Enable CLSI Editing Works only with 14 digit
Codabar type lengths. This option will perform
CLSI type editing before the information is
transmitted to the host.
³ 1 0 7 7 0 6
* Do Not Enable CLSI Editing
³ 1 0 0 4 1 0
Enable Codabar Mod-16 Check Digit
³ 1 0 0 4 0 0
* Disable Codabar Mod-16 Check Digit
³ 1 0 0 4 1 1
Enable Codabar “7-Check” Check Digit
³ 1 0 0 4 0 1
* Disable Codabar “7-Check” Check Digit
³ 1 0 8 0 0 6
* Transmit Codabar Check Digit
³ 1 0 8 0 1 6
Don’t Transmit Codabar Check Digit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MetroSelect Eclipse MS 5145 and is the answer not in the manual?

Honeywell MetroSelect Eclipse MS 5145 Specifications

General IconGeneral
BrandHoneywell
ModelMetroSelect Eclipse MS 5145
CategoryScanner
LanguageEnglish

Related product manuals