EasyManua.ls Logo

Honeywell MetroSelect Eclipse MS 5145 - Data Transmission Delays and Timeouts

Honeywell MetroSelect Eclipse MS 5145
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7–6
Data Transmission Delays
Use these codes to select the amount of delay between sending data
characters from the scanner to the host. This helps prevent the scanner from
overflowing host-input buffers.
³ 8 1 8 8 1 0
* 1 msec Intercharacter Delay
³ 8 1 8 8 1 0 0
10 msec Intercharacter Delay
³ 8 1 8 8 2 5 0
25 msec Intercharacter Delay
³ 9 1 8 8 0 0
~ Variable msec Intercharacter Delay Scan this
bar code and a sequence of code bytes on page
16–1 to set the delay between characters sent to
the host system (range from 1 to 255 msecs.).
³ 8 1 8 8 0 0
No Intercharacter Delay
³ 9 1 9 3 0 0
~ Variable Inter-Record Delay
³ 1 1 9 3 1 7
Turn Off Laser During Inter-Record Delay
³ 1 1 9 3 0 7
* Leave Laser On During Inter-Record Delay

Table of Contents

Related product manuals