Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
Max Datagram Size shows the currently set value (typically a
default value, but this can also be set by the management station).
The show sflow <instance> sampling-polling [port-list] command displays infor-
mation about sFlow sampling and polling on the switch. You can specify a list
or range of ports for which to view sampling information.
ProCurve# show sflow 2 sampling-polling 1-4
Number denotes the sampling/polling instance to which the receiver is coupled.
Port | Sampling Dropped
+
---
| Polling
| Enabled Rate Header Samples | Enabled Interval
----- + -------- -------- ------ ---------- ------- --------
1 Yes(2)
40 128 1234567890 ---
2 --- --- --- 0
Yes(1) 60
3 No(1) 0 100 898703 No 30
4 Yes(3) 50 128 0 No(3) 0
Figure 13-15. Example of Viewing sFlow Sampling and Polling Information
Note The sampling and polling instances (noted in parentheses) coupled to a
specific receiver instance are assigned dynamically, and so the instance
numbers may not always match. The key thing to note is whether sampling or
polling is enabled on a port, and the sampling rates or polling intervals for the
receiver instance configured on each port.