EasyManuals Logo

HP StorageWorks 12000 User Manual

HP StorageWorks 12000
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
SolutionPossible causesSymptom
Use the VLS's LUN masking feature
to restrict the number of virtual
devices the host sees on the VLS FC
host ports, so it only sees the virtual
devices it needs to see. Then, use
the VLS's LUN mapping feature to
assign LUNs to the virtual devices
the host can see, such that the virtu-
al device LUN numbers include a
LUN0 and no gaps in the LUN
numbering. See LUN Masking
(v3.x) and LUN Mapping (v3.x) for
instructions.
Remove the gap in the LUN number-
ing by editing the host's LUN map-
ping (see LUN Mapping (v3.x)), or
if a virtual device has been des-
troyed on the VLS, creating a gap
in the LUN numbering, restart the
VLS device emulations. The VLS
firmware will reassign LUNs to the
virtual devices as necessary to re-
move any gaps in the LUN number-
ing. See Restarting VLS Device
Emulations.
There is a gap in the LUN number-
ing on the FC host port. Most oper-
ating systems will stop looking for
virtual devices on an FC host port
once a gap in the LUN numbering
is detected. For example, if LUN0,
LUN1, and LUN3 are mapped to
an FC host port, the operating sys-
tem will see LUN0 and LUN1.
When it does not find a LUN2, it
will assume there are no more
LUNs on the port and stop looking.
Troubleshooting220

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 12000 and is the answer not in the manual?

HP StorageWorks 12000 Specifications

General IconGeneral
Product NameHP StorageWorks 12000
Management SoftwareHP StorageWorks Command View
Form FactorRack-mountable
TypeGateway
CategoryGateway
ConnectivityiSCSI