101
crosses the rising threshold multiple times before it crosses the falling threshold, only the first
crossing triggers a rising alarm event.
Sample types for the alarm group and the private alarm group
The RMON agent supports the following sample types:
absolute—RMON compares the value of the monitored variable with the rising and falling
thresholds at the end of the sampling interval.
delta—RMON subtracts the value of the monitored variable at the previous sample from the
current value, and then compares the difference with the rising and falling thresholds.
Protocols and standards
RFC 4502, Remote Network Monitoring Management Information Base Version 2
RFC 2819, Remote Network Monitoring Management Information Base Status of this Memo
Configuring the RMON statistics function
RMON implements the statistics function through the Ethernet statistics group and the history group.
The Ethernet statistics group provides the cumulative statistic for a variable from the time the
statistics entry is created to the current time. For more information about the configuration, see
"Creating an RMON Ethernet statistics entry."
The histo
ry group provides statistics that are sampled for a variable for each sampling interval. The
history group uses the history control table to control sampling, and it stores samples in the history
table. For more information about the configuration, see "Creating an RMON history control entry."
Creating an RMON Ethernet statistics entry
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Enter Ethernet
interface view.
interface
interface-type
interface-number
N/A
3. Create an RMON
Ethernet statistics
entry.
rmon statistics
entry-number
[
owner
text ]
By default, no RMON Ethernet statistics
entry exists.
You can create only one RMON
statistics entry for an Ethernet interface.
You can create a maximum of 200
RMON statistics entries on a device.
When the limit is reached, you cannot
add new entries.
Creating an RMON history control entry
You can configure multiple history control entries for one interface, but you must make sure their
entry numbers and sampling intervals are different.
You can create a history control entry successfully even if the specified bucket size exceeds the
available history table size. RMON will set the bucket size as closely to the expected bucket size as
possible.

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs