Task Command
Display the diagnostic log file configuration.
display diagnostic-logfile summary
Display the information of each output destination.
display info-center
Display the state and the log information of the log
buffer.
display logbuffer
[
reverse
] [
level
severity |
size
buffersize |
slot
slot-number ] *
Display a summary of the log buffer.
display logbuffer summary
[
level
severity
| slot
slot-number ] *
Display the configuration of the log file.
display logfile summary
Clear the log buffer.
reset logbuffer
Setting the minimum storage time for logs
Use this feature to set the minimum storage time for logs in the log buffer and log file. A log will not be
automatically deleted from the log buffer or log file if the time elapsed since the log was generated is
shorter than the minimum storage time. By default, the system automatically deletes the earliest logs
when the log buffer of log file is full, regardless of the log storage time.
To set the log minimum storage time:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Set the log minimum
storage time.
info-center syslog min-age
min-age
By default, the log minimum
storage time is not
configured.
Information center configuration examples
Configuration example for outputting logs to the console
Network requirements
Configure the device to output to the console FTP logs that have a severity level of at least warning.
Figure 24 Network diagram
Configuration procedure
# Enable the information center.
<Device> system-view
[Device] info-center enable
# Disable log output to the console.
[Device] info-center source default console deny
To avoid output of unnecessary information, disable all modules from outputting log information to
the specified destination (console in this example) before you configure the output rule.

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs

Related product manuals