EasyManuals Logo

HPE FlexFabric 5700 Series User Manual

HPE FlexFabric 5700 Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
66
Configuring the information center
The information center on a device classifies and manages logs for all modules so that network
administrators can monitor network performance and troubleshoot network problems.
Overview
The information center receives logs generated by source modules and outputs logs to different
destinations according to user-defined output rules. You can classify, filter, and output logs based on
source modules. To view the supported source modules, use info-center source ?.
Figure 23 Information center diagram
By default, the information center is enabled. It affects system performance to some degree while
processing large amounts of information.
Log types
Logs are classified into the following types:
Common logs—Record common system information. Unless otherwise specified, the term
"logs" in this document refers to common logs.
Diagnostic logs—Record debug messages.
Security logs—Record security information, such as authentication and authorization
information.
Hidden logs—Record log information not displayed on the terminal, such as input commands.
Trace logs—Record system tracing and debug messages, which can be viewed only after the
devkit package is installed.
Log levels
Logs are classified into eight severity levels from 0 through 7 in descending order. The device
outputs logs with a severity level that is higher than or equal to the specified level. For example, if you
configure an output rule with a severity level of 6 (informational), logs that have a severity level from
0 to 6 are output.
Table 6 Log levels
Severit
y value
Level Description
0 Emergency The system is unusable. For example, the system authorization has expired.
1 Alert
Action must be taken immediately. For example, traffic on an interface exceeds
the upper limit.
2 Critical
Critical condition. For example, the device temperature exceeds the upper
limit, the power module fails, or the fan tray fails.

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs