To create an RMON history control entry:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Enter Ethernet
interface view.
interface
interface-type
interface-number
N/A
3. Create an RMON
history control entry
rmon history
entry-number
buckets
number
interval
sampling-interval [
owner
text ]
By default, no RMON history control
entries exist.
You can create multiple RMON history
control entries for an Ethernet interface.
You can create a maximum of 200
RMON history control entries on a
device. When the limit is reached, you
cannot add new entries.
Configuring the RMON alarm function
When you configure the RMON alarm function, follow these guidelines:
To send notifications to the NMS when an alarm is triggered, configure the SNMP agent as
described in "Configuring SNMP" before config
uring the RMON alarm function.
For a new event, alarm, or private alarm entry to be created:
{ The entry must not have the same set of parameters as an existing entry.
{ The maximum number of entries is not reached.
Table 17 shows
the parameters to be compared for duplication and the entry limits.
Table 17 RMON configuration restrictions
Entry Parameters to be compared
Maximum
number of entries
Event
Event description (description string)
Event type (log, trap, logtrap, or none)
Community name (security-string)
60
Alarm
Alarm variable (alarm-variable)
Sampling interval (sampling-interval)
Sample type (absolute or delta)
Rising threshold (threshold-value1)
Falling threshold (threshold-value2)
60
Private alarm
Alarm variable formula (prialarm-formula)
Sampling interval (sampling-interval)
Sample type (absolute or delta)
Rising threshold (threshold-value1)
Falling threshold (threshold-value2)
50
To configure the RMON alarm function:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. (Optional.) Create an
event entry in the
rmon
event
entry-number [
description
string ] {
log
|
log-trap
security-string |
none
|
trap
By default, the RMON
event table does not

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs