120 7. Calibration and Maintenance GSP9700 Series Road Force Measurement System Operation
Place the inner Dataset
®
arm at downward position “4.” Tap the foot pedal once or
press “Enter Cal Step.”
1
2
3
Place the inner Dataset
®
arm at downward position “5.” Tap the foot pedal once or
press “Enter Cal Step.”
Place the inner Dataset
®
arm at downward position “6.” Tap the foot pedal once or
press “Enter Cal Step.”
Remove the calibration weight from the calibration tool and return it to its storage
position.
Position the calibration tool parallel to the spindle shaft on the hub using the hub
mounting slot as shown.
Place the inner Dataset
®
arm at the position “7.” Tap the foot pedal once or press
“Enter Cal Step.”
9
8
7
Place the inner Dataset
®
arm at the position “8.” Tap the foot pedal once or press
“Enter Cal Step.”
Place the inner Dataset
®
arm at the position “9.” Tap the foot pedal once or press
“Enter Cal Step.”
Inner Dataset
®
arm calibration is complete.