GSP9700 Series Road Force Measurement System Operation 5. Balancing Features and Options 89
Move the inner Dataset
®
arm to the far right weight position, using the DOWNWARD
arm position. Enter the data by pressing the foot pedal.
After inputting weight plane(s), the Split Spoke
®
feature may be initiated by the
following steps before returning the arm to the “home” position:
Move the inner Dataset
arm to a position centered behind a spoke,
using the DOWNWARD arm position. Enter the data by pressing the foot
pedal.
Rotate the wheel to position the Dataset
®
arm behind an adjacent spoke
(nearest spoke in either direction). Enter the data by pressing the foot
pedal.
Return the inner Dataset
®
arm to the home position.
Close safety hood.
Press the green “START” button if “Hood Autostart” is disabled.