2.7.6 Calibrate
You can use this function to calibrate the tilt sensor and
guide wire.
Calibrate tilt sensor
To calibrate, i.e. reset the tilt sensor: Place the robotic
lawnmower on a horizontal surface. Place the cursor
on Calibrate tilt sensor and press OK.
Calibrate Guides
Guide wires are calibrated automatically during the
starting sequence and after factory rest of the mower.
A manual calibration from this menu alternative may be
necessary in certain situations however. For example,
if a new guide wire is installed or the charging station
installation is changed, e.g. stretching the boundary wire
or guide wire.
To calibrate installed guide wires:
1. Place mower in charging station.
2. Enable Calibrate guides from the menu.
3. Press OK and start the mower.
4. Calibration is complete once the mower starts the
blade motor.
Calibrate tilt sensor
Calibrate guides
Info
History, total
History, trip
Test
Special settings
Calibrate