2) When I/O2 is Fieldbus type (Type of extension I/O is either of CC/CC2/DV/DV2/PR/EP/EC/PRT)
Type Port No. Function Type Port No. Function
000 300 ALM (LED on the front panel)
001 301 RDY (LED on the front panel)
002 302 EMG (LED on the front panel)
003 303 System reservation
004 304 HPS (LED on the front panel)
005 305
006 306
007 307
008 308
009 309
010 310
011 311
012 312
013 313
014 314
Internal
DI
(I/O1)
015
System reservation
Internal
DO
(I/O1)
315
System reservation
External
DI
(I/O1)
016
to
031
General-purpose input
External
DO
(I/O1)
316
to
331
General-purpose output
032 332 7-segment user display digit
033 333 7-segment user display digit
034 334 System reservation
035 335 System reservation
036 336 System reservation
037 337 7-segment display refresh
038 338 7-segment user/system alternate
039 339 7-segment user display specification
040 340 DT0 (7-segment user display bit)
041 341 DT1 (7-segment user display bit)
042 342 DT2 (7-segment user display bit)
043 343 DT3 (7-segment user display bit)
044 344 DT4 (7-segment user display bit)
045 345 DT5 (7-segment user display bit)
046 346 DT6 (7-segment user display bit)
Internal
DI
(I/O1)
047
System reservation
Internal
DO
(I/O1)
347 System reservation
048 Program start
348 Alarm output
049 349 READY output
050 350 Emergency-stop output
051 351
052 352
053 353
054
General-purpose input
354
055
Program number indication (BCD:1
BIN:1) *
355
056
Program number indication (BCD:2
BIN:2) *
356
057
Program number indication (BCD:4
BIN:4) *
357
058
Program number indication (BCD:81
BIN:8) *
358
059
Program number indication (BCD:10
BIN:16) *
359
060
Program number indication (BCD:20
BIN:32) *
360
061
Program number indication (BCD:40
BIN:64) *
361
062 362
063
General-purpose input
363
General-purpose output
External
DI
(I/O2)
064
to
295
General-purpose input
External
DO
(I/O2)
364
to
595
General-purpose output
* Switching over between BCD and BID in Program Number Indication should be conducted in IO
Parameter No. 30 Input Function Select 000.
(1:Program start BCD, 2:Program start binary(BIN))