Chapter 5 I/O Parameter
142
5.9 Permission of SIO/PIO Program Startup with Password
By setting to Parameter “Manual Operation Type” (Other Parameter No. 21), the parameter
can be changed so SIO program startup and PIO program startup cannot be conducted
without inputting a password.
(1) PC software
1) Setting = 0 (Always enable edit and SIO/PIO start)
Functions
Operation type Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO
program
start
PIO
program
start
With safety speed Not required
Without safety
speed
Not required
2) Setting = 1 (Select edit and start (with password))
Functions
Operation type Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO
program
start
PIO
program
start
Edit and jog Not required
SIO start and jog
(safety speed)
1817
SIO start and jog 1818
SIO/PIO start and
jog
1819
(2) Teaching pendant
1) Setting = 0 (Always enable edit and SIO/PIO start)
Functions
Safety-speed
enable selection
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
Enable Not required
Disable Not required
2) Setting = 1 (Select edit and start (with password))
Functions
Safety-speed
enable selection
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
(Note 1)
Enable Not required
Note 2
Disable 1818
Note 2
Functions
PIO start
prohibition
selection
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
(Note 1)
Prohibit Not required
Note 3
Enable 1819
Note 3
Note 1 PIO program start is enabled only in modes other than the edit mode.
Note 2 In accordance with the “PIO start prohibition selection” setting.
Note 3 In accordance with the “Safety-speed enable” setting.