If you do not save your configuration before you power off the printer, all of the
new parameter values that have not been saved to NVRAM will be erased. When
you power the printer on again, the power-on configuration will load. If no
configuration has been designated as the power-on configuration, the factory
configuration will load.
Note: To avoid overwriting an existing custom set, the Protect Custom Sets
parameter must be set to ENABLE. See page 66 for details.
Step Key LCD Results Notes
1. Press
STOP
NOT READY Places the printer in NOT READY mode.
2.
OPERATOR MENU UNLOCKED Unlocks the Operator Menu, which
allows you to make configuration
changes.
3.
MENU
OPERATOR MENU PRINTER
CONTROL
Displays the first Configuration Main
Menu option, PRINTER CONTROL.
4.
UNTIL
OPERATOR MENU
CONFIGURATION
MANAGEMENT
Moves to the Configuration
Management menu option.
5.
ENTER
CONFIGURATION
MANAGEMENT RECALL
CUSTOM SET
Selects the CONFIGURATION
MANAGEMENT menu. The RECALL
CUSTOM SET option appears.
6.
UNTIL
CONFIGURATION
MANAGEMENT SAVE
CURRENT VALUES
Moves to the SAVE CURRENT VALUES
option.
7.
ENTER
SAVE CURRENT VALUES 1* Selects the SAVE CURRENT VALUES
menu.
8.
UNTIL
SAVE CURRENT VALUES 2 Scrolls through the list of custom sets 1 -
8.
9.
ENTER
SAVING CONFIGURATION Selects the SAVE CURRENT VALUES
option. The message “SAVING
CONFIGURATION” appears briefly.
10.
STOP
NOT READY Returns the printer to the NOT READY
mode.
Chapter 3. Configuring the Printer 41