Table 7. DS4800 Storage Subsystem weights (continued)
Unit
Weight
Maximum
1
Empty
2
Shipping
3
1
Maximum weight indicates a storage subsystem with two battery modules installed. Each
battery module weighs 1.1 kg (2.5 lb).
2
Empty weight indicates a storage subsystem with all components removed.
3
Shipping weight indicates the maximum weight of the storage subsystem and all shipping
material.
Table 8. DS4800 Storage Subsystem component weights
Unit Weight
RAID controller 6.36 kg (14 lb)
Power supply-fan 3.72 kg (8.2 lb)
Interconnect-battery unit 5.36 kg (11.8 lb)
Battery module 1.134 kg (2.5 lb)
Shipping dimensions
Table 9 lists shipping carton dimensions. The height shown includes the height of
the pallet.
Table 9. DS4800 Storage Subsystem shipping carton dimensions
Height Width Depth
44.4 cm (17.5 in.) 62.2 cm (24.5 in.) 78.7 cm (31.0 in.)
Environmental requirements and specifications
This section describes the environmental conditions that are prerequisite to
installing the unit, and heat and sound conditions that are generated by normal
operation of the unit.
Temperature and humidity
Table 10 lists the acceptable temperature and humidity ranges in which the storage
subsystem is designed to operate.
Important: The recommended operating environment air temperature is 22° C (72°
F) or lower.
Table 10. Temperature and humidity requirements
Condition Parameter Requirement
Temperature
1
Operating range 10° - 35° C (50° - 95° F)
Maximum rate of change 10° C (18° F) per hour
Storage range 1° - 60° C (33° - 140° F)
Maximum rate of change 15° C (27° F) per hour
Transit range -40° C to 65° C (-40° F to
149° F)
Maximum rate of change 20° C (36° F) per hour
22 IBM System Storage DS4800 Storage Subsystem: Installation, User’s, and Maintenance Guide