v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code Message Description Action
W.50001 [W.50001] A DIMM has been
disabled due to an error
detected during POST.
DIMM Disabled. Note: Each time you install or
remove a DIMM, you must
disconnect the server from the power
source; then, wait 10 seconds before
restarting the server.
1. Make sure the DIMM is installed
correctly (see “Installing a
memory module” on page 34).
2. If the DIMM was disabled
because of a memory fault, follow
the suggested actions for that
error event.
3. If no memory fault is recorded in
the logs and no DIMM connector
error LED is lit, you can re-enable
the DIMM through the Setup
utility or the Advanced Settings
Utility (ASU).
S.51003 [S.51003] An uncorrectable
memory error was detected in
DIMM slot % on rank %.
[S.51003] An uncorrectable
memory error was detected on
processor % channel %. The
failing DIMM within the
channel could not be
determined.
[S.51003] An uncorrectable
memory error has been
detected during POST.
Fatal Memory Error Occurred.
1. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
2. If the problem remains, replace
the affected DIMMs.
3. (Trained technician only) If the
problem occurs on the same
DIMM connector, check the
DIMM connector. If the connector
contains any foreign material or is
damaged, replace the system
board.
4. (Trained technician only) Remove
the affected microprocessor and
check the microprocessor socket
pins for any damaged pins. If a
damage is found, replace the
system board.
5. (Trained technician only) Replace
the affected microprocessor (see
“Removing a microprocessor and
heat sink” on page 347 and
“Replacing a microprocessor and
heat sink” on page 349).
128 System x3530 M4 Type 7160: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3530 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3530 M4 and is the answer not in the manual?

IBM System x3530 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3530 M4
CategoryServer
LanguageEnglish

Related product manuals