10. Reconnect the SAS signal cables and remote RAID battery cable to the
ServeRAID adapter, if you removed them earlier.
11. Reinstall the PCI riser-card assemblies with the adapters, if any were installed
(see “Replacing a PCI riser-card assembly” on page 66).
12. Reinstall the air baffle (see “Replacing the air baffle” on page 66).
13. Reinstall the cover (see “Replacing the server top cover” on page 67).
14. Reconnect the power cords and any cables that you removed.
15. Turn on the peripheral devices and the server.
Important: Perform the following updates:
v Either update the server with the latest RAID firmware or restore the
pre-existing firmware from a diskette or CD image.
v Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on
page 92).
v Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 95).
v If you purchased a Feature on Demand, make sure that you reactivate the
feature using the instructions in the Feature on Demand documentation.
Removing and replacing consumable and structural parts
Replacement of consumable parts and structural parts is your responsibility. If IBM
installs a consumable part or structural part at your request, you will be charged
for the installation.
The illustrations in this document might differ slightly from the hardware.
Removing the server top cover
Attention: If you release the cover latch and remove the cover while the server is
running, the server will lose power and turn off automatically. After you reinstall
the cover, you can power-on the server again.
To remove the server top cover, complete the following steps:
1. Read the safety information that begins on page Safety and “Installation
guidelines” on page 30.
2. Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3. If the server has been installed in a rack, press the two release latches on the
front of the server and remove the server out of the rack enclosure.
Attention: Two or more people are required to remove the system from a rack
cabinet.
4. Loosen the two thumbscrews that secure the cover to the rear of the server.
5. Press on the two blue grip points and slide the cover toward the rear; then, lift
the cover off the server and set it aside.
362 System x3530 M4 Type 7160: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3530 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3530 M4 and is the answer not in the manual?

IBM System x3530 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3530 M4
CategoryServer
LanguageEnglish

Related product manuals