3. Connect the remote battery cable to the remote battery cable connector to the
ServeRAID adapter. Route the remote battery cable in the server as shown in
the following illustration.
Attention: Make sure that the cable is not pinched and does not cover any
connectors or obstruct any components on the system board.
4. Reinstall the PCI riser-card assembly (see “Replacing a PCI riser-card assembly”
on page 66).
5. Replace the cover (see “Replacing the server top cover” on page 67).
6. Reconnect the power cord and any cables that you removed.
7. Turn on the peripheral devices and the server.
Removing a USB embedded hypervisor flash device
To remove a hypervisor flash device, complete the following steps:
1. Read the safety information that begins on page Safety and “Installation
guidelines” on page 30.
2. Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3. Remove the top cover (see “Removing the server top cover” on page 33).
4. Remove PCI riser-card assembly 1 (see “Removing a PCI riser-card assembly”
on page 328).
5. Locate the USB embedded hypervisor flash device connector on the system
board.
6. Slide the lockbar on the flash device connector to the unlocked position and
pull the USB flash device out of the connector.
318 System x3530 M4 Type 7160: Installation and Service Guide